PTM505C pressure tube gas pulse testing machine

Equipment overview

       PTM505C series pressure tube gas pulse fatigue testing machine is used in automotive intake manifold, pressure tube, intercooling tube, one-way valve body, nylon tube and other cyclic pressure durability and temperature durability test。The test process and data acquisition are controlled by computer, and the equipment has high technical integration, good stability, simple operation, reliable and durable。Widely used in automotive technology centers, product quality inspection institutes, auto parts factories, research institutes and other institutions。

 

Functional characteristics

1. Using PC for data acquisition, process control and data processing;The interface dynamically displays test data and draws real-time time-pressure waveform diagram;

2. Medium temperature PID regulation can automatically adjust the given voltage output time of the heating furnace according to the output flow of the medium, stable temperature control, high efficiency and energy saving, with ultra-high temperature, ultra-high pressure, leakage sound and light alarm, emergency shutdown, access control system functions;

3. The computer automatically stores the test data and generates the test report to print out;You can query the temperature of each point on the curve。Display the highest and lowest values of studio temperature and medium temperature during the test;

4. The peak pressure is automatically adjusted by proportional valve and sensor, which can be set on the interface and is easy to operate。The computer controlled test can sample pressure, temperature, waveform, pulse frequency and so on in real time。Can export test report in Office document format, and can edit freely。

5, the comprehensive test chamber has a transparent observation window, the test can be observed with the naked eye during the test, the operation space is large, easy for personnel to work, the pipeline connection design is reasonable, prevent leakage, and easy maintenance。

 

Technical index

Technical project

Parameter index

Equipment type

PTM505C series

Specimen type

Pressurization tube, intercooling tube, intake manifold, one-way valve body, nylon tube, etc

Reference standard

GMW16153-2009, GMW15408-2008, VW_60562-2010, JB-T10506, GB/T23338

Peak pressure

0.1~ 0.5MPa Arbitrary setting

Pulse frequency

0.1 ~0.5Hz Arbitrary setting

Pulse waveform

Trapezoid wave, sine wave

Pulse frequency

Arbitrarily set according to test standard requirements

Test medium

High temperature compressed air

Medium temperature

Room temperature RT+10~230℃ can be selected

Flow range

5~100L/min adjustable

Ambient temperature

-40~150℃ or -70~230℃ can be selected

Installation mode

Hose connection;Adjustable tooling

Number of specimens

1~6 paths per time (the smaller the content of the specimen, the more paths)

Extension attachment

High and low temperature environment box (optional)

Multi-functional manipulator (optional)


It is widely used in auto parts factories, product quality inspection institutes, third-party testing centers, scientific research colleges and other fields。