PTM705C intercooler gas pulse testing machine

Equipment overview

       PTM705C series gas pulse fatigue testing machine is used for high temperature gas pressure alternating test of automobile air cooling intercooler, water cooling intercooler and pipe joint。Check whether the intercooler can complete the number of cycles specified in the standard under high and low temperature conditions。It is widely used in auto parts factories, product quality inspection institutes, third-party testing centers, scientific research colleges and other fields。

 

Functional characteristics

1. Tubular electric heating element is used as heating element, with advanced structure, high thermal efficiency, good mechanical strength, corrosion resistance, wear resistance and other characteristics;

2. The peak pressure is automatically adjusted by proportional valve and sensor, which can be set on the interface and is easy to operate.

3. The medium temperature PID regulation can automatically adjust the given voltage output time of the heating wire according to the output flow rate of the medium, and the temperature control is stable, efficient and energy saving;

4, computer control test can be real-time sampling pressure, temperature, waveform, pulse frequency and other content。Can export test report in Office document format, and can edit freely;

5, the comprehensive test chamber has a transparent observation window, the test can be observed with the naked eye during the test, the operation space is large, easy for personnel to work, the pipeline connection design is reasonable, prevent leakage, and easy maintenance。

 

Technical index

Technical project

Parameter index

Equipment type

Wantest PTM705C series

Specimen type

Air cooled intercooler, water cooled intercooler, etc

Reference standard

GB/T23338-2009,QC/T828-2010,JB/T10408-2004 GMW14191-2010,GMW15803,TL82132-2007, etc

Peak pressure

0.1~0.7MPa Arbitrary setting

Pulse frequency

0.05 ~1.0Hz Any setting

Pulse waveform

Trapezoid wave, sine wave

Pulse frequency

Arbitrarily set according to test standard requirements

Test medium

High temperature compressed air, etc

Medium temperature

Room temperature RT or RT+10~230℃ can be selected

Ambient temperature

Room temperature RT or -40~150℃ can be selected

Installation mode

Hose connection

Number of specimens

1~3 paths (the smaller the content volume of the specimen, the more paths)

Extension attachment

High and low temperature environment box (optional)